Get UBL up and running again
All the changes to get the code into compliance with Marlin coding standards made UBL sick. This pretty much gets UBL back up and running.
This commit is contained in:
parent
5de1da2b3c
commit
b8e4a6970b
3 changed files with 57 additions and 50 deletions
|
|
@ -2266,7 +2266,7 @@ static void clean_up_after_endstop_or_probe_move() {
|
|||
|
||||
#endif // HAS_BED_PROBE
|
||||
|
||||
#if PLANNER_LEVELING
|
||||
#if PLANNER_LEVELING || ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
/**
|
||||
* Turn bed leveling on or off, fixing the current
|
||||
* position as-needed.
|
||||
|
|
@ -2309,10 +2309,7 @@ static void clean_up_after_endstop_or_probe_move() {
|
|||
planner.unapply_leveling(current_position);
|
||||
}
|
||||
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
if (ubl.state.eeprom_storage_slot == 0) {
|
||||
ubl.state.active = enable;
|
||||
ubl.store_state();
|
||||
}
|
||||
#endif
|
||||
}
|
||||
|
||||
|
|
@ -2363,6 +2360,8 @@ static void clean_up_after_endstop_or_probe_move() {
|
|||
for (uint8_t x = 0; x < ABL_GRID_MAX_POINTS_X; x++)
|
||||
for (uint8_t y = 0; y < ABL_GRID_MAX_POINTS_Y; y++)
|
||||
bed_level_grid[x][y] = UNPROBED;
|
||||
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
ubl.reset();
|
||||
#endif
|
||||
#endif
|
||||
}
|
||||
|
|
@ -3482,6 +3481,11 @@ inline void gcode_G4() {
|
|||
*
|
||||
*/
|
||||
inline void gcode_G28() {
|
||||
#if ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
bool bed_leveling_state_at_entry=0;
|
||||
bed_leveling_state_at_entry = ubl.state.active;
|
||||
set_bed_leveling_enabled(false);
|
||||
#endif
|
||||
|
||||
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
||||
if (DEBUGGING(LEVELING)) {
|
||||
|
|
@ -3638,6 +3642,10 @@ inline void gcode_G28() {
|
|||
#endif
|
||||
|
||||
// Enable mesh leveling again
|
||||
#if ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
set_bed_leveling_enabled(bed_leveling_state_at_entry);
|
||||
#endif
|
||||
|
||||
#if ENABLED(MESH_BED_LEVELING)
|
||||
if (mbl.reactivate()) {
|
||||
set_bed_leveling_enabled(true);
|
||||
|
|
@ -5060,6 +5068,10 @@ inline void gcode_M42() {
|
|||
* regenerated.
|
||||
*/
|
||||
inline void gcode_M48() {
|
||||
#if ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
bool bed_leveling_state_at_entry=0;
|
||||
bed_leveling_state_at_entry = ubl.state.active;
|
||||
#endif
|
||||
|
||||
if (axis_unhomed_error(true, true, true)) return;
|
||||
|
||||
|
|
@ -5283,6 +5295,11 @@ inline void gcode_M42() {
|
|||
set_bed_leveling_enabled(abl_was_enabled);
|
||||
#endif
|
||||
|
||||
#if ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
set_bed_leveling_enabled(bed_leveling_state_at_entry);
|
||||
ubl.state.active = bed_leveling_state_at_entry;
|
||||
#endif
|
||||
|
||||
report_current_position();
|
||||
}
|
||||
|
||||
|
|
@ -8511,7 +8528,7 @@ void process_next_command() {
|
|||
gcode_G28();
|
||||
break;
|
||||
|
||||
#if PLANNER_LEVELING
|
||||
#if PLANNER_LEVELING || HAS_ABL
|
||||
case 29: // G29 Detailed Z probe, probes the bed at 3 or more points,
|
||||
// or provides access to the UBL System if enabled.
|
||||
gcode_G29();
|
||||
|
|
|
|||
Loading…